Evaluation of the Does Reduction Potential Using a Breast Positioning Technique for Organ-based Tube Current Modulated CT Examinations

dc.contributor.advisor

Samei, Ehsan

dc.contributor.author

Fu, Wanyi

dc.date.accessioned

2016-06-06T16:49:59Z

dc.date.available

2018-05-10T08:17:10Z

dc.date.issued

2016

dc.department

Electrical and Computer Engineering

dc.description.abstract

Purpose: The purpose of this work was to investigate the breast dose saving potential of a breast positioning technique (BP) for thoracic CT examinations with organ-based tube current modulation (OTCM).

Methods: The study included 13 female patient models (XCAT, age range: 27-65 y.o., weight range: 52 to 105.8 kg). Each model was modified to simulate three breast sizes in standard supine geometry. The modeled breasts were further deformed, emulating a BP that would constrain the breasts within 120° anterior tube current (mA) reduction zone. The tube current value of the CT examination was modeled using an attenuation-based program, which reduces the radiation dose to 20% in the anterior region with a corresponding increase to the posterior region. A validated Monte Carlo program was used to estimate organ doses with a typical clinical system (SOMATOM Definition Flash, Siemens Healthcare). The simulated organ doses and organ doses normalized by CTDIvol were compared between attenuation-based tube current modulation (ATCM), OTCM, and OTCM with BP (OTCMBP).

Results: On average, compared to ATCM, OTCM reduced the breast dose by 19.3±4.5%, whereas OTCMBP reduced breast dose by 36.6±6.9% (an additional 21.3±7.3%). The dose saving of OTCMBP was more significant for larger breasts (on average 32, 38, and 44% reduction for 0.5, 1.5, and 2.5 kg breasts, respectively). Compared to ATCM, OTCMBP also reduced thymus and heart dose by 12.1 ± 6.3% and 13.1 ± 5.4%, respectively.

Conclusions: In thoracic CT examinations, OTCM with a breast positioning technique can markedly reduce unnecessary exposure to the radiosensitive organs in the anterior chest wall, specifically breast tissue. The breast dose reduction is more notable for women with larger breasts.

dc.identifier.uri

https://hdl.handle.net/10161/12299

dc.subject

Electrical engineering

dc.subject

Medical imaging

dc.subject

Biomedical engineering

dc.subject

breasts

dc.subject

Monte Carlo

dc.subject

organ-based tube current modulation

dc.subject

organ dose

dc.subject

radiosensitive organs

dc.subject

thoracic CT

dc.title

Evaluation of the Does Reduction Potential Using a Breast Positioning Technique for Organ-based Tube Current Modulated CT Examinations

dc.type

Master's thesis

duke.embargo.months

23

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Fu_duke_0066N_13205.pdf
Size:
2.43 MB
Format:
Adobe Portable Document Format

Collections