Time-of-Flight PET Compared to Increased Scan Time in Low-Contrast Regions
dc.contributor.advisor | Turkington, Timothy G | |
dc.contributor.author | Smith, Timothy Jordan | |
dc.date.accessioned | 2011-05-20T19:13:30Z | |
dc.date.available | 2011-05-20T19:13:30Z | |
dc.date.issued | 2011 | |
dc.department | Medical Physics | |
dc.description.abstract | Positron Emission Tomography is a coincidence-detection-based nuclear imaging modality that has increased in clinical prevalence over the last two decades. Measures have recently been taken to improve the practice, specifically the synergistic combination with CT, and implementation of iterative reconstruction. The time-of- flight (TOF) technique is another improvement theorized early in PET development, which reduces image noise by measuring the difference in coincident photon detection times. It was difficult to implement at the time of inception because of limited technologies, but better detectors and electronics have recently made TOF feasible for clinical use. Its gain in image quality has been measured by various methods, but is difficult to quantify because of tradeoffs inherent in count-based imaging. This work set out to investigate the image quality gained with TOF imaging by determining the effective non-TOF scan time required to achieve equivalent image quality as TOF. Methods: We used the TOF-capable GE Discovery 690 PET/CT scanner with ~600 ps timing resolution to acquire high-count list-mode data of hot spheres, cold bottles, and a novel low-contrast bead insert housed in three phantoms of increasing diameters. These data were reconstructed with and without TOF information into shorter images of 30 sec, 1, 2, 4 and 8 min, using the OS-EM reconstruction algorithm with 16 subsets and 1, 2, 3, 5 and 10 iterations each. Up to 16 replicates of each image were produced. Regions of interest were drawn on the high-count images and subsequently applied to all images in each set. These data were averaged across the replicate image sets for statistical power and were used to calculate contrast, background variability and replicate variability for regions within each phantom scan. Background variability was measured as the standard deviation of 1 cm ROI means spread throughout the background, while replicate noise was measured as the pixel deviation across replicated images. The contrast for each unique phantom region and scan time were plotted versus the two noise measures, and a unique quantification method was devised to calculate the scan time equivalent for images reconstructed with TOF versus those without. Results: Visual evaluation showed universal improvement in image quality. Hot spheres were more easily resolved, cold regions were colder, and the low-contrast phantom became clearer overall. Gains were also higher as a function of phantom size. Plotting contrast versus the two variability measures demonstrated greater gains for larger phantoms than small. The quantification method delivered easily interpretable results that correlated with visual and graphical evaluation. Hot spheres showed between 1.6× and 2.5× scan time gain factor, while cold bottles showed between 3.8× and 4.3× gain, when measuring background variability as the noise component. Three areas of the low- contrast insert were considered, and showed results generally lying between those of the cold and hot inserts, with one exception demonstrating 9.15× and 10.35× gains for the background and replicate variability measures, respectively. Measuring gains using the replicate noise demonstrated similar quality gain as the background variability. Conclusions: The results of this work agree with previous studies stating that TOF information contributes significantly to PET image quality when utilized during reconstruction, specifically for hot lesions and cold regions. This was shown visually, graphically, and quantitatively. The unique quantification method devised, which uses image quality plots to generate gain factors in terms of equivalent non-TOF scan time, was successfully implemented and yielded relatively consistent results. The new phantom insert developed to mimic lower-contrast regions present in human abdominal images was successfully imaged, showing a 1.3× to 4.2× overall gain in equivalent scan time across all phantom sizes. Trends were observed in several aspects of these results that may subjugate TOF quality gain even further. Cold areas recover better than hot lesions, as expected, but low-contrast areas show varying levels of TOF improvement, and tend to lie between those demonstrated for hot and cold regions. Finally, similar results were found when considering background variability and replicate variability noise measures, which can be considered further validation of the image quality results. | |
dc.identifier.uri | ||
dc.subject | Medical imaging and radiology | |
dc.subject | GE Discovery 690 | |
dc.subject | PET | |
dc.subject | Positron emission tomography | |
dc.subject | Time of Flight | |
dc.subject | TOF | |
dc.title | Time-of-Flight PET Compared to Increased Scan Time in Low-Contrast Regions | |
dc.type | Master's thesis |