Are the Arbeitsgemeinschaft Für Osteosynthesefragen (AO) Principles for Long Bone Fractures Applicable to 3-Column Osteotomy to Reduce Rod Fracture Rates?

dc.contributor.author

Virk, Sohrab

dc.contributor.author

Lafage, Renaud

dc.contributor.author

Bess, Shay

dc.contributor.author

Shaffrey, Christopher

dc.contributor.author

Kim, Han J

dc.contributor.author

Ames, Christopher

dc.contributor.author

Burton, Doug

dc.contributor.author

Gupta, Munish

dc.contributor.author

Smith, Justin S

dc.contributor.author

Eastlack, Robert

dc.contributor.author

Klineberg, Eric

dc.contributor.author

Mundis, Gregory

dc.contributor.author

Schwab, Frank

dc.contributor.author

Lafage, Virginie

dc.contributor.author

International Spine Study Group

dc.date.accessioned

2023-06-15T17:37:42Z

dc.date.available

2023-06-15T17:37:42Z

dc.date.issued

2022-06

dc.date.updated

2023-06-15T17:37:41Z

dc.description.abstract

Objective

The aim was to determine whether applying Arbeitsgemeinschaft für Osteosynthesefragen (AO) principles for external fixation of long bone fracture to patients with a 3-column osteotomy (3CO) would be associated with reduced rod fracture (RF) rates.

Summary of background data

AO dictate principles to follow when fixating long bone fractures: (1) decrease bone-rod distance; (2) increase the number of connecting rods; (3) increase the diameter of rods; (4) increase the working length of screws; (5) use multiaxial fixation. We hypothesized that applying these principles to patients undergoing a 3CO reduces the rate of RF.

Methods

Patients were categorized as having RF versus no rod fracture (non-RF). Details on location and type of instrumentation were collected. Dedicated software was used to calculate the distance between osteotomy site and adjacent pedicle screws, angle between screws and the distance between the osteotomy site and rod. Classic sagittal spinopelvic parameters were evaluated.

Results

The study included 170 patients (34=RF, 136=non-RF). There was no difference in age (P=0.224), sagittal vertical axis correction (P=0.287), or lumbar lordosis correction (P=0.36). There was no difference in number of screws cephalad (P=0.62) or caudal (P=0.31) to 3CO site. There was a lower rate of RF for patients with >2 rods versus 2 rods (P<0.001). Patients with multiplanar rod fixation had a lower rod fracture rate (P=0.01). For patients with only 2 rods (N=68), the non-RF cohort had adjacent screws that trended to have less angulation to each other (P=0.06) and adjacent screws that had a larger working length (P=0.03).

Conclusions

A portion of AO principles can be applied to 3CO to reduce RF rates. Placing more rods around a 3CO site, placing rods in multiple planes, and placing adjacent screws with a larger working length around the 3CO site is associated with lower RF rates.
dc.identifier

01933606-900000000-98900

dc.identifier.issn

2380-0186

dc.identifier.issn

2380-0194

dc.identifier.uri

https://hdl.handle.net/10161/28015

dc.language

eng

dc.publisher

Ovid Technologies (Wolters Kluwer Health)

dc.relation.ispartof

Clinical spine surgery

dc.relation.isversionof

10.1097/bsd.0000000000001289

dc.subject

International Spine Study Group

dc.subject

Humans

dc.subject

Lordosis

dc.subject

Postoperative Complications

dc.subject

Spinal Fusion

dc.subject

Osteotomy

dc.subject

Fractures, Bone

dc.title

Are the Arbeitsgemeinschaft Für Osteosynthesefragen (AO) Principles for Long Bone Fractures Applicable to 3-Column Osteotomy to Reduce Rod Fracture Rates?

dc.type

Journal article

duke.contributor.orcid

Shaffrey, Christopher|0000-0001-9760-8386

pubs.begin-page

E429

pubs.end-page

E437

pubs.issue

5

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Orthopaedic Surgery

pubs.organisational-group

Neurosurgery

pubs.publication-status

Published

pubs.volume

35

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Are the Arbeitsgemeinschaft Fur Osteosynthesefragen (AO) Principles for Long Bone Fractures Applicable to 3-Column Osteotomy to Reduce Rod Fracture Rates.pdf
Size:
558.07 KB
Format:
Adobe Portable Document Format