Dose-Guided Automatic IMRT Planning: A Feasibility Study

dc.contributor.advisor

Wu, Qingrong (Jackie)

dc.contributor.author

Sheng, Yang

dc.date.accessioned

2014-05-14T19:21:56Z

dc.date.available

2015-05-09T04:30:05Z

dc.date.issued

2014

dc.department

Medical Physics

dc.description.abstract

Purpose: To develop and evaluate an automatic IMRT planning technique for prostate cancer utilizing prior expert plan's dose distribution as guidance.

Methods and Materials: In this study, the anatomical information of prostate cancer cases was parameterized and quantified into two measures: the percent distance-to-prostate (PDP) and the concaveness angle. Based on these two quantities, a plan atlas composed of 5 expert prostate IMRT plans was built out of a 70-case pool at our institution using k-medoids clustering analysis.

Extra 20 cases were used as query cases to evaluate the dose-guided automatic planning (DAP) scheme. Each query case was matched to an atlas case based on PTV-OAR anatomical features followed by deformable registration to enhance fine local matching. Using the deformation field, the expert dose in the matched atlas case was warped onto the query case, creating the goal dose conformal to the query case's anatomy. Dose volume histograms (DVHs) objectives were sampled from the goal dose to guide automatic IMRT treatment planning. Dosimetric comparison between DAP plans and clinical plans were performed.

Results: Generating goal dose is highly efficient by using MIMTM workflows. The deformable registration provides high-quality goal dose tailored to query case's anatomy in terms of the dose falloff at the PTV-OAR boundary and the overall conformity. Automatic planning in EclipseTM takes ~2.5 min (~70 iterations) without human intervention. Compared to clinical plans, DAP plans improved the conformity index from 0.85±0.04 to 0.88±0.02 (p=0.0045), the bladder-gEUD from 40.7±3.2 Gy to 40.0±3.1 Gy (p=0.0003), and rectum-gEUD from 40.4±2.0 Gy to 39.9±2.1 Gy (p=0.0167). Other dosimetric parameter is similar (p>0.05): homogeneity indices are 7.4±0.9% and 7.1±1.5%, for DAP plans and clinical plans, respectively.

Conclusions: Dose-guided automatic treatment planning is feasible and efficient. Atlas-based patient-specific dose objectives can effectively guide the optimizer to achieve similar or better plan quality compared to clinical plans.

dc.identifier.uri

https://hdl.handle.net/10161/8805

dc.subject

Medicine

dc.subject

atlas

dc.subject

Automatic

dc.subject

Clustering

dc.subject

goal dose

dc.subject

IMRT

dc.subject

registration

dc.title

Dose-Guided Automatic IMRT Planning: A Feasibility Study

dc.type

Master's thesis

duke.embargo.months

12

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Sheng_duke_0066N_12322.pdf
Size:
1.28 MB
Format:
Adobe Portable Document Format

Collections