Evaluation of a field appropriate membrane filtration method for the detection of Vibrio cholerae for the measurement of biosand filter performance in the Artibonite Valley, Haiti.

dc.contributor.author

Thomson, Ashley A

dc.contributor.author

Gunsch, Claudia K

dc.coverage.spatial

Netherlands

dc.date.accessioned

2016-01-06T17:41:31Z

dc.date.issued

2015-08

dc.description.abstract

Biosand filters in the Artibonite Valley of Haiti, the epicenter of the cholera epidemic that began in October 2010, were tested for total coliform and Vibrio cholerae removal efficiencies. While coliform are often used as an indicator organism for pathogenic bacteria, a correlation has never been established linking the concentration of coliform and V. cholerae, the causative agent for cholera. Hence, a method for field enumeration of V. cholerae was developed and tested. To this end, a plate count test utilizing membrane filtration technique was developed to measure viable V. cholerae cell concentration in the field. Method accuracy was confirmed by comparing plate count concentrations to microscopic counts. Additionally, biosand filters were sampled and removal efficiencies of V. cholerae and coliform bacteria compared. The correlation between removal efficiency and time in operation, biofilm ("schmutzdecke") composition, and idle time was also investigated. The plate count method for V. cholerae was found to accurately reflect microscope counts and was shown to be effective in the field. Overall, coliform concentration was not an appropriate indicator of V. cholerae concentration. In 90% of the influent samples from the study, coliform underestimated V. cholerae concentration (n = 26). Furthermore, coliform removal efficiency was higher than for V. cholerae hence providing a conservative measurement. Finally, time in operation and idle time were found to be important parameters controlling performance. Overall, this method shows promise for field applications and should be expanded to additional studies to confirm its efficacy to test for V. cholerae in various source waters.

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/26135641

dc.identifier.eissn

1573-2959

dc.identifier.uri

https://hdl.handle.net/10161/11462

dc.language

eng

dc.publisher

Springer Science and Business Media LLC

dc.relation.ispartof

Environ Monit Assess

dc.relation.isversionof

10.1007/s10661-015-4677-1

dc.subject

Cholera

dc.subject

Environmental Monitoring

dc.subject

Filtration

dc.subject

Haiti

dc.subject

Membranes, Artificial

dc.subject

Vibrio cholerae

dc.subject

Water Microbiology

dc.title

Evaluation of a field appropriate membrane filtration method for the detection of Vibrio cholerae for the measurement of biosand filter performance in the Artibonite Valley, Haiti.

dc.type

Journal article

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/26135641

pubs.begin-page

484

pubs.issue

8

pubs.organisational-group

Civil and Environmental Engineering

pubs.organisational-group

Duke

pubs.organisational-group

Environmental Sciences and Policy

pubs.organisational-group

Nicholas School of the Environment

pubs.organisational-group

Pratt School of Engineering

pubs.publication-status

Published

pubs.volume

187

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Final BSF Manuscript.docx
Size:
3.49 MB
Format:
Unknown data format