Patient-specific organ dose and in-vivo image quality assessment in clinical CT.

dc.contributor.author

Fu, Wanyi

dc.contributor.author

Sharma, Shobhit

dc.contributor.author

Solomon, Justin

dc.contributor.author

Ria, Francesco

dc.contributor.author

Setiawan, Hananiel

dc.contributor.author

Ding, Aiping

dc.contributor.author

Segars, William P

dc.contributor.author

Samei, Ehsan

dc.date.accessioned

2025-06-30T20:38:19Z

dc.date.available

2025-06-30T20:38:19Z

dc.date.issued

2025-06-26

dc.description.abstract

PURPOSE: To develop and characterize individualized dose and quality measures at organ level compared to their generic counterparts across a clinical CT dataset. MATERIALS AND METHODS: The study included 9801 chest-abdomen-pelvis and abdomen-pelvis CT exams (7,763 patients, mean age, 56 ± 17 years; 4113 women) representing 20 unique protocols. For each exam, patient-specific organ dose of all radiosensitive organs was estimated using a validated method by generating personalized computational phantoms and Monte Carlo simulations. Effective dose (EOD) was calculated by weighted sum of the organ doses. Liver dose, ODliver, noise in the liver, Nliver, and observer model detectability, d', were assessed within the liver as examples of individualized, organ-based image assessment measurements. The organ-based measurements (ODliver, EOD, and Nliver) were compared to their generic counterparts: ssize-specific ddose estimates (SSDE), effective dose based on dose length product (EDLP), and whole-body noise (Nglobal), respectively. RESULTS: Generic dose values were substantially higher than individualized estimates for SSDE vs. ODliver (median of all exams: 51.2 %, p < 0.001) and EDLP vs. EDOD (median: 41.0 %, p < 0.001). Nglobal was generally lower than Nliver (median: -7.2 %, p < 0.001). The correlation relationships of EOD and d' were substantially varied (R2 range: 0-0.5) for different patient sizes and scan parameters. CONCLUSIONS: Demonstrated across a population of exams, individualized organ-based measurements of dose and quality are feasible. Generic measures cannot fully represent individualized organ-based values. The correlation relationships between individualized dose and image quality values varies for different vendors and protocols, implying imaging optimization is best when done semi-independently for each factor using individualized measurements.

dc.identifier

S1120-1797(25)00127-9

dc.identifier.issn

1120-1797

dc.identifier.issn

1724-191X

dc.identifier.uri

https://hdl.handle.net/10161/32520

dc.language

eng

dc.publisher

Elsevier BV

dc.relation.ispartof

Phys Med

dc.relation.isversionof

10.1016/j.ejmp.2025.105017

dc.rights.uri

https://creativecommons.org/licenses/by-nc/4.0

dc.subject

Computed tomography

dc.subject

Monte Carlo

dc.subject

Quality control

dc.subject

computational phantom

dc.subject

organ dose

dc.title

Patient-specific organ dose and in-vivo image quality assessment in clinical CT.

dc.type

Journal article

duke.contributor.orcid

Ria, Francesco|0000-0001-5902-7396

duke.contributor.orcid

Ding, Aiping|0000-0002-6971-7283

pubs.begin-page

105017

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Staff

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Radiology

pubs.organisational-group

Duke Cancer Institute

pubs.publication-status

Published online

pubs.volume

136

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CT_patient_specific_dose_and_IQ_Fu_et_al_2025_Physica_Medica.pdf
Size:
3.09 MB
Format:
Adobe Portable Document Format
Description:
Published version