Sources of variability in quantification of cardiovascular magnetic resonance infarct size - reproducibility among three core laboratories.

dc.contributor.author

Klem, Igor

dc.contributor.author

Heiberg, Einar

dc.contributor.author

Van Assche, Lowie

dc.contributor.author

Parker, Michele A

dc.contributor.author

Kim, Han W

dc.contributor.author

Grizzard, John D

dc.contributor.author

Arheden, Håkan

dc.contributor.author

Kim, Raymond J

dc.coverage.spatial

England

dc.date.accessioned

2018-01-05T21:21:04Z

dc.date.available

2018-01-05T21:21:04Z

dc.date.issued

2017-08-11

dc.description.abstract

BACKGROUND: Acute myocardial infarct (AMI) size depicted by late gadolinium enhancement cardiovascular magnetic resonance (CMR) is increasingly used as an efficacy endpoint in randomized trials comparing AMI therapies. Infarct size is quantified using manual planimetry (MANUAL), visual scoring (VISUAL), or automated techniques using signal-intensity thresholding (AUTO). Although AUTO is considered the most reproducible, prior studies did not account for the subjective determination of endocardial/epicardial borders, which all methods require. For MANUAL and VISUAL, prior studies did not address how to treat intermediate signal intensities due to partial volume. METHODS: To assess sources of variability, AMI size was measured in 30 patients and 12 controls by 3 core-laboratories using 8 methods, each separated by more than 2 months time (n = 720 evaluations). The methods were: (1,2) AUTOSegment, AUTOFWHM (using Segment software or the full-width-at-half-maximum algorithm, respectively); (3,4) AUTO-UCSegment, AUTO-UCFWHM (user correction for endocardial border pixels, no-reflow, etc.); (5) MANUAL; (6) MANUAL-ISI (adjustment for intermediate signal-intensities); (7) VISUAL; (8) VISUAL-ISI. RESULTS: Mean infarct size varied between 16.8% and 27.2% of LV mass depending on method. Even automated techniques with no user interaction for infarct borders resulted in significant within-patient variability given the need to subjectively trace endocardial/epicardial contours. The coefficient-of-variation (CV) was 10.6% and 14.6% for AUTOSegment and AUTOFWHM, respectively. For manual and visual categories, reproducibility was improved when intermediate signal-intensities were considered (MANUAL-ISI vs MANUAL: CV = 8.3% vs 14.4%; p = 0.03; VISUAL-ISI vs VISUAL: CV = 8.4% vs 10.9%; p = 0.01). For AUTO-UCSegment, MANUAL-ISI, and VISUAL-ISI (best technique in each category) within-patient variability due to the quantification method was less than 10% of total variability, and the required sample sizes for detecting a 5% absolute difference in infarct size were 62, 63, and 62 patients, respectively. CONCLUSION: Among CMR core-laboratories, an important source of variability in infarct size quantification is the subjective delineation of endocardial/epicardial borders. When intermediate signal intensities are considered in manual planimetry and visual scoring, reproducibility and impact on sample size are similar to automated techniques.

dc.identifier

https://www.ncbi.nlm.nih.gov/pubmed/28800739

dc.identifier

10.1186/s12968-017-0378-y

dc.identifier.eissn

1532-429X

dc.identifier.uri

https://hdl.handle.net/10161/15962

dc.language

eng

dc.publisher

Springer Science and Business Media LLC

dc.relation.ispartof

J Cardiovasc Magn Reson

dc.relation.isversionof

10.1186/s12968-017-0378-y

dc.title

Sources of variability in quantification of cardiovascular magnetic resonance infarct size - reproducibility among three core laboratories.

dc.type

Journal article

pubs.author-url

https://www.ncbi.nlm.nih.gov/pubmed/28800739

pubs.begin-page

62

pubs.issue

1

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Medicine

pubs.organisational-group

Medicine, Cardiology

pubs.organisational-group

Radiology

pubs.organisational-group

School of Medicine

pubs.organisational-group

Temp group - logins allowed

pubs.publication-status

Published online

pubs.volume

19

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Sources of variability in quantification of cardiovascular magnetic resonance infarct size - reproducibility among three core laboratories.pdf
Size:
3.16 MB
Format:
Adobe Portable Document Format