Correcting Motion Artifacts in Multi-Shot Diffusion-Weighted EPI Using Iterative Phase Cycling

Loading...
Thumbnail Image

Date

2012

Journal Title

Journal ISSN

Volume Title

Repository Usage Stats

863
views
773
downloads

Abstract

Diffusion-weighted MRI (DWI) is an essential tool in clinical applications such as detecting ischemic stroke, and in research applications studying neuronal connectivity in the brain. Diffusion-weighted imaging with multi-shot echo-planar acquisition (DWEPI) offers several advantages over single-shot EPI, including improved spatial resolution and reduced off-resonance and susceptibility artifacts. However a major limitation of multi-shot DWEPI is its sensitivity to patient motion during the application of diffusion gradients; the motion generates phase errors which vary from shot to shot, resulting in artifacts in the reconstructed image.

Most current methods for correcting motion-induced artifacts involve the use of navigator echoes to estimate the shot-to-shot phase errors. Accurate navigator information comes at the expense of increased scan times however, which is generally undesirable. The aim of this study is to therefore develop and demonstrate the use of an alternative phase estimation technique, iterative phase-cycling, as a new method to correct motion artifacts in DWI without the use of navigators. The developed method involves an iterative column by column estimation of phase errors in the aliased image and reconstruction of an artifact free image using the estimated errors.

In this study the technique was applied to correct artifacts in simulated images, hybrid-simulated images, and true four-shot DWEPI images. Accuracy of the phase-cycling method was evaluated by computing residual image errors and ghost-to-noise ratios after correction. The efficiency of phase-cycling was evaluated by recording computation times of the correction process. Multiple optimization techniques were developed and used in the experiments, and the accuracy/efficiency of these techniques were also assessed.

Results of the experiments demonstrated the ability of phase-cycling to greatly reduce motion-induced artifacts in multi-shot DWEPI at reasonable computation times. The phase-cycling model used in this study accurately estimated linear and nonlinear errors along the frequency encoding direction and linear errors along the phase encoding direction. An additional mathematical framework is presented illustrating the potential of phase-cycling to correct nonlinear errors along the phase encoding direction in future work.

The study establishes the developed technique as a unique and effective method for correcting motion artifacts in DWEPI without the cost of increased scan times.

Description

Provenance

Citation

Citation

Guhaniyogi, Shayan (2012). Correcting Motion Artifacts in Multi-Shot Diffusion-Weighted EPI Using Iterative Phase Cycling. Master's thesis, Duke University. Retrieved from https://hdl.handle.net/10161/5452.

Collections


Except where otherwise noted, student scholarship that was shared on DukeSpace after 2009 is made available to the public under a Creative Commons Attribution / Non-commercial / No derivatives (CC-BY-NC-ND) license. All rights in student work shared on DukeSpace before 2009 remain with the author and/or their designee, whose permission may be required for reuse.