Statistical methods for the assessment of EQAPOL proficiency testing: ELISpot, Luminex, and Flow Cytometry.

dc.contributor.author

Rountree, Wes

dc.contributor.author

Vandergrift, Nathan

dc.contributor.author

Bainbridge, John

dc.contributor.author

Sanchez, Ana M

dc.contributor.author

Denny, Thomas N

dc.coverage.spatial

Netherlands

dc.date.accessioned

2017-06-01T19:29:09Z

dc.date.available

2017-06-01T19:29:09Z

dc.date.issued

2014-07

dc.description.abstract

In September 2011 Duke University was awarded a contract to develop the National Institutes of Health/National Institute of Allergy and Infectious Diseases (NIH/NIAID) External Quality Assurance Program Oversight Laboratory (EQAPOL). Through EQAPOL, proficiency testing programs are administered for Interferon-γ (IFN-γ) Enzyme-linked immunosorbent spot (ELISpot), Intracellular Cytokine Staining Flow Cytometry (ICS) and Luminex-based cytokine assays. One of the charges of the EQAPOL program was to apply statistical methods to determine overall site performance. We utilized various statistical methods for each program to find the most appropriate for assessing laboratory performance using the consensus average as the target value. Accuracy ranges were calculated based on Wald-type confidence intervals, exact Poisson confidence intervals, or via simulations. Given the nature of proficiency testing data, which has repeated measures within donor/sample made across several laboratories; the use of mixed effects models with alpha adjustments for multiple comparisons was also explored. Mixed effects models were found to be the most useful method to assess laboratory performance with respect to accuracy to the consensus. Model based approaches to the proficiency testing data in EQAPOL will continue to be utilized. Mixed effects models also provided a means of performing more complex analyses that would address secondary research questions regarding within and between laboratory variability as well as longitudinal analyses.

dc.identifier

https://www.ncbi.nlm.nih.gov/pubmed/24456626

dc.identifier

S0022-1759(14)00017-9

dc.identifier.eissn

1872-7905

dc.identifier.uri

https://hdl.handle.net/10161/14689

dc.language

eng

dc.publisher

Elsevier BV

dc.relation.ispartof

Journal of Immunological Methods

dc.relation.isversionof

10.1016/j.jim.2014.01.007

dc.subject

ELISpot

dc.subject

Flow Cytometry

dc.subject

Luminex

dc.subject

Mixed effects models

dc.subject

Poisson

dc.subject

Proficiency testing

dc.subject

Biomarkers

dc.subject

Cytokines

dc.subject

Data Interpretation, Statistical

dc.subject

Enzyme-Linked Immunospot Assay

dc.subject

Flow Cytometry

dc.subject

Guideline Adherence

dc.subject

Humans

dc.subject

Interferon-gamma Release Tests

dc.subject

Laboratories

dc.subject

Laboratory Proficiency Testing

dc.subject

Models, Statistical

dc.subject

Monitoring, Immunologic

dc.subject

Observer Variation

dc.subject

Practice Guidelines as Topic

dc.subject

Predictive Value of Tests

dc.subject

Program Development

dc.subject

Program Evaluation

dc.subject

Quality Control

dc.subject

Quality Indicators, Health Care

dc.subject

Reproducibility of Results

dc.subject

Specimen Handling

dc.title

Statistical methods for the assessment of EQAPOL proficiency testing: ELISpot, Luminex, and Flow Cytometry.

dc.type

Journal article

pubs.author-url

https://www.ncbi.nlm.nih.gov/pubmed/24456626

pubs.begin-page

72

pubs.end-page

81

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Duke Human Vaccine Institute

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Medicine

pubs.organisational-group

Medicine, Duke Human Vaccine Institute

pubs.organisational-group

School of Medicine

pubs.publication-status

Published

pubs.volume

409

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PMID24456626.pdf
Size:
636.4 KB
Format:
Adobe Portable Document Format