Assisted Fluid Management Software Guidance for Intraoperative Fluid Administration.

Abstract

Background

Excessive or inadequate fluid administration causes complications, but despite this, fluid administration during noncardiac surgery is highly variable. Goal-directed management helps optimize the amount and timing of fluid administration; however, implementation is difficult because algorithms are complex. The authors therefore tested the performance of the Acumen Assisted Fluid Management software (Edwards Lifesciences, USA), which is designed to guide optimal intravenous fluid administration during surgery.

Methods

In this multicenter, prospective, single-arm cohort evaluation, the authors enrolled 330 adults scheduled for moderate- to high-risk noncardiac surgery that required arterial catheter insertion and mechanical ventilation. Clinicians chose a fluid strategy based on a desired 10%, 15%, or 20% increase in stroke volume (SV) in response to a fluid bolus. Dedicated fluid management software prompted "test" or "recommended" boluses, and clinicians were free to initiate a "user" bolus of 100 to 500 ml of crystalloid or colloid. Clinicians were free to accept or decline the software prompts. The authors primarily compared the fraction of software-recommended boluses that produced suitable increases in SV to a 30% reference rate. On an exploratory basis, we compared responses to software-recommended and clinician-initiated boluses.

Results

Four hundred twenty-four of 479 (89%) software-recommended fluid boluses and 508 of 592 (86%) clinician-initiated fluid boluses were analyzed per protocol. Of those, 66% (95% CI, 62 to 70%) of delivered fluid boluses recommended by the software resulted in desired increases in SV, compared with the 30% reference rate, whereas only 41% (95% CI, 38 to 44%) of clinician-initiated boluses did (P < 0.0001). The mean ± SD increase in SV after boluses recommended by the software was 14.2 ± 13.9% versus 8.3 ± 12.1% (P < 0.0001) for those initiated by clinicians.

Conclusions

Fluid boluses recommended by the software resulted in desired SV increases more often, and with greater absolute SV increase, than clinician-initiated boluses. Automated assessment of fluid responsiveness may help clinicians optimize intraoperative fluid management during noncardiac surgery.

Editor’s perspective

Department

Description

Provenance

Citation

Published Version (Please cite this version)

10.1097/aln.0000000000003790

Publication Info

Maheshwari, Kamal, Gaurav Malhotra, Xiaodong Bao, Peiman Lahsaei, William R Hand, Neal W Fleming, Davinder Ramsingh, Miriam M Treggiari, et al. (2021). Assisted Fluid Management Software Guidance for Intraoperative Fluid Administration. Anesthesiology, 135(2). pp. 273–283. 10.1097/aln.0000000000003790 Retrieved from https://hdl.handle.net/10161/24781.

This is constructed from limited available data and may be imprecise. To cite this article, please review & use the official citation provided by the journal.

Scholars@Duke

Treggiari

Miriam Treggiari

Paul G. Barash Distinguished Professor of Anesthesiology
Miller

Timothy Ellis Miller

Professor of Anesthesiology

Clinical and research interests are Enhanced Recovery and Perioperative Medicine; with particular interests in fluid management, and perioperative optimization of the high-risk non-cardiac surgery patient.


Unless otherwise indicated, scholarly articles published by Duke faculty members are made available here with a CC-BY-NC (Creative Commons Attribution Non-Commercial) license, as enabled by the Duke Open Access Policy. If you wish to use the materials in ways not already permitted under CC-BY-NC, please consult the copyright owner. Other materials are made available here through the author’s grant of a non-exclusive license to make their work openly accessible.