The impact of gestational age and fetal weight on the risk of failure of spinal anesthesia for cesarean delivery.

dc.contributor.author

Adesope, OA

dc.contributor.author

Einhorn, LM

dc.contributor.author

Olufolabi, AJ

dc.contributor.author

Cooter, M

dc.contributor.author

Habib, AS

dc.coverage.spatial

Netherlands

dc.date.accessioned

2016-10-19T12:46:13Z

dc.date.issued

2016-05

dc.description.abstract

BACKGROUND: There are limited data about spinal dosing for cesarean delivery in preterm parturients. We investigated the hypothesis that preterm gestation is associated with an increased incidence of inadequate spinal anesthesia for cesarean delivery compared with term gestation. METHODS: We searched our perioperative database for women who underwent cesarean delivery under spinal or combined spinal-epidural anesthesia with hyperbaric bupivacaine ⩾10.5mg. The primary outcome was the incidence of inadequate surgical anesthesia needing conversion to general anesthesia or repetition or supplementation of the block. We divided patients into four categories: <28, 28 to <32, 32 to <37 and ⩾37weeks of gestation. The chi-square test was used to compare failure rates and a multivariable regression analysis was performed to investigate potential confounders of the relationship between gestational age and failure. RESULTS: A total of 5015 patients (3387 term and 1628 preterm) were included. There were 278 failures (5.5%). The incidence of failure was higher in preterm versus term patients (6.4% vs. 5.1%, P=0.02). Failure rates were 10.8%, 7.7%, 5.3% and 5% for <28, 28 to <32, 32 to <37 and ⩾37weeks of gestation, respectively. In the multivariable model, low birth weight (P<0.0001), gestational age (P=0.03), ethnicity (P=0.02) and use of combined spinal-epidural anesthesia (P<0.0001) were significantly associated with failure. CONCLUSIONS: At standard spinal doses of hyperbaric bupivacaine used in our practice (⩾10.5mg), there were higher odds of inadequate surgical anesthesia in preterm parturients. When adjusting for potential confounders, low birth weight was the main factor associated with failure.

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/27020240

dc.identifier

S0959-289X(16)00028-5

dc.identifier.eissn

1532-3374

dc.identifier.uri

https://hdl.handle.net/10161/12959

dc.language

eng

dc.publisher

Elsevier BV

dc.relation.ispartof

Int J Obstet Anesth

dc.relation.isversionof

10.1016/j.ijoa.2016.01.007

dc.subject

Anesthesia

dc.subject

Cesarean delivery

dc.subject

Combined spinal-epidural

dc.subject

Failed anesthesia

dc.subject

Gestation age

dc.subject

Spinal

dc.title

The impact of gestational age and fetal weight on the risk of failure of spinal anesthesia for cesarean delivery.

dc.type

Journal article

duke.contributor.orcid

Einhorn, LM|0000-0003-4541-2247

duke.contributor.orcid

Olufolabi, AJ|0000-0001-8902-7805

duke.contributor.orcid

Habib, AS|0000-0002-6980-1856

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/27020240

pubs.begin-page

8

pubs.end-page

14

pubs.organisational-group

Anesthesiology

pubs.organisational-group

Anesthesiology, Pediatrics

pubs.organisational-group

Anesthesiology, Women's

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Global Health Institute

pubs.organisational-group

Institutes and Provost's Academic Units

pubs.organisational-group

Obstetrics and Gynecology

pubs.organisational-group

School of Medicine

pubs.organisational-group

University Institutes and Centers

pubs.publication-status

Published

pubs.volume

26

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
gestationalageandspinal.pdf
Size:
267.88 KB
Format:
Adobe Portable Document Format
Description:
Published version