Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

dc.contributor.author

Vardhan, M

dc.contributor.author

Gounley, J

dc.contributor.author

Chen, SJ

dc.contributor.author

Nair, P

dc.contributor.author

Wei, W

dc.contributor.author

Hegele, L

dc.contributor.author

Kusner, J

dc.contributor.author

Kahn, AM

dc.contributor.author

Frakes, D

dc.contributor.author

Leopold, JA

dc.contributor.author

Randles, A

dc.date.accessioned

2024-06-27T18:08:36Z

dc.date.available

2024-06-27T18:08:36Z

dc.date.issued

2022-01-01

dc.description.abstract

Background and objective: Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Methods: Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. Results: There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). Conclusion: The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

dc.identifier.issn

2674-0702

dc.identifier.uri

https://hdl.handle.net/10161/31210

dc.publisher

Frontiers Media SA

dc.relation.ispartof

Frontiers in Systems Biology

dc.relation.isversionof

10.3389/fsysb.2022.930396

dc.rights.uri

https://creativecommons.org/licenses/by-nc/4.0

dc.title

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

dc.type

Journal article

duke.contributor.orcid

Randles, A|0000-0001-6318-3885

pubs.organisational-group

Duke

pubs.organisational-group

Pratt School of Engineering

pubs.organisational-group

School of Medicine

pubs.organisational-group

Trinity College of Arts & Sciences

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Biomedical Engineering

pubs.organisational-group

Thomas Lord Department of Mechanical Engineering and Materials Science

pubs.organisational-group

Duke Cancer Institute

pubs.organisational-group

Computer Science

pubs.publication-status

Published

pubs.volume

2

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
fsysb-02-930396 (4).pdf
Size:
1.75 MB
Format:
Adobe Portable Document Format
Description:
Published version