The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis: a finite element analysis.

dc.contributor.author

Bess, Shay

dc.contributor.author

Harris, Jeffrey E

dc.contributor.author

Turner, Alexander WL

dc.contributor.author

LaFage, Virginie

dc.contributor.author

Smith, Justin S

dc.contributor.author

Shaffrey, Christopher I

dc.contributor.author

Schwab, Frank J

dc.contributor.author

Haid, Regis W

dc.date.accessioned

2023-07-09T21:48:11Z

dc.date.available

2023-07-09T21:48:11Z

dc.date.issued

2017-01

dc.date.updated

2023-07-09T21:48:08Z

dc.description.abstract

OBJECTIVE Proximal junctional kyphosis (PJK) remains problematic following multilevel instrumented spine surgery. Previous biomechanical studies indicate that providing less rigid fixation at the cranial aspect of a long posterior instrumented construct, via transition rods or hooks at the upper instrumented vertebra (UIV), may provide a gradual transition to normal motion and prevent PJK. The purpose of this study was to evaluate the ability of posterior anchored polyethylene tethers to distribute proximal motion segment stiffness in long instrumented spine constructs. METHODS A finite element model of a T7-L5 spine segment was created to evaluate range of motion (ROM), intradiscal pressure, pedicle screw loads, and forces in the posterior ligament complex within and adjacent to the proximal terminus of an instrumented spine construct. Six models were tested: 1) intact spine; 2) bilateral, segmental pedicle screws (PS) at all levels from T-11 through L-5; 3) bilateral pedicle screws from T-12 to L-5 and transverse process hooks (TPH) at T-11 (the UIV); 4) pedicle screws from T-11 to L5 and 1-level tethers from T-10 to T-11 (TE-UIV+1); 5) pedicle screws from T-11 to L-5 and 2-level tethers from T-9 to T-11 (TE-UIV+2); and 6) pedicle screws and 3-level tethers from T-8 to T-11 (TE-UIV+3). RESULTS Proximal-segment range of motion (ROM) for the PS construct increased from 16% at UIV-1 to 91% at UIV. Proximal-segment ROM for the TPH construct increased from 27% at UIV-1 to 92% at UIV. Posterior tether constructs distributed ROM at the UIV and cranial adjacent segments most effectively; ROM for TE-UIV+1 was 14% of the intact model at UIV-1, 76% at UIV, and 98% at UIV+1. ROM for TE-UIV+2 was 10% at UIV-1, 51% at UIV, 69% at UIV+1, and 97% at UIV+2. ROM for TE-UIV+3 was 7% at UIV-1, 33% at UIV, 45% at UIV+1, and 64% at UIV+2. Proximal segment intradiscal pressures, pedicle screw loads, and ligament forces in the posterior ligament complex were progressively reduced with increasing number of posterior tethers used. CONCLUSIONS Finite element analysis of long instrumented spine constructs demonstrated that posterior tethers created a more gradual transition in ROM and adjacent-segment stress from the instrumented to the noninstrumented spine compared with all PS and TPH constructs. Posterior tethers may limit the biomechanical risk factor for PJK; however, further clinical research is needed to evaluate clinical efficacy.

dc.identifier.issn

1547-5654

dc.identifier.issn

1547-5646

dc.identifier.uri

https://hdl.handle.net/10161/28397

dc.language

eng

dc.publisher

Journal of Neurosurgery Publishing Group (JNSPG)

dc.relation.ispartof

Journal of neurosurgery. Spine

dc.relation.isversionof

10.3171/2016.6.spine151477

dc.subject

Longitudinal Ligaments

dc.subject

Lumbar Vertebrae

dc.subject

Thoracic Vertebrae

dc.subject

Humans

dc.subject

Kyphosis

dc.subject

Range of Motion, Articular

dc.subject

Finite Element Analysis

dc.subject

Pressure

dc.subject

Models, Biological

dc.subject

Stress, Physiological

dc.subject

Biomechanical Phenomena

dc.subject

Pedicle Screws

dc.title

The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis: a finite element analysis.

dc.type

Journal article

duke.contributor.orcid

Shaffrey, Christopher I|0000-0001-9760-8386

pubs.begin-page

125

pubs.end-page

133

pubs.issue

1

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Orthopaedic Surgery

pubs.organisational-group

Neurosurgery

pubs.publication-status

Published

pubs.volume

26

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis a finite element analysis..pdf
Size:
4.02 MB
Format: