Assessment of 70-keV virtual monoenergetic spectral images in abdominal CT imaging: A comparison study to conventional polychromatic 120-kVp images.

dc.contributor.author

Rassouli, Negin

dc.contributor.author

Chalian, Hamid

dc.contributor.author

Rajiah, Prabhakar

dc.contributor.author

Dhanantwari, Amar

dc.contributor.author

Landeras, Luis

dc.coverage.spatial

United States

dc.date.accessioned

2017-08-07T01:23:42Z

dc.date.available

2017-08-07T01:23:42Z

dc.date.issued

2017-04-18

dc.description.abstract

PURPOSE: To evaluate the image quality of 70-keV virtual monoenergetic (monoE) abdominal CT images compared to 120-kVp polychromatic images generated from a spectral detector CT (SDCT) scanner. METHODS: This prospective study included generation of a 120-kVp polychromatic dataset and a 70-keV virtual monoE dataset after a single contrast-enhanced CT acquisition on a SDCT scanner (Philips Healthcare) during portal venous phase. The attenuation values (HU), noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured in the liver, spleen, pancreas, kidney, aorta, portal vein, and muscle. The subjective image quality including noise, soft tissue contrast, sharpness, and overall image quality were graded on a 5-point Likert scale by two radiologists independently (1-worst image quality, 5-best image quality). Statistical analysis was performed using paired sample t test and Fleiss's Kappa. RESULTS: Fifty-five patients (54.3 ± 16.8 y/o; 28 M, 27 F) were recruited. The noise of target organs was significantly lower in virtual monoE images in comparison to polychromatic images (p < 0.001). The SNR and CNR were significantly higher in virtual monoE images (p < 0.001 for both). Subjective image quality of 70-keV virtual monoE images was significantly better (p < 0.001) for all evaluated parameters. Median scores for all subjective parameters were 3.0 versus 4.0 for polychromatic vs virtual monoE images, respectively. The inter-reader agreement for overall image quality was good (Kappa were 0.767 and 0.762 for polychromatic and virtual monoE images, respectively). CONCLUSION: In abdominal imaging, 70-keV virtual monoE CT images demonstrated significantly better noise, SNR, CNR, and subjective score compared to conventional 120-kVp polychromatic images.

dc.identifier

https://www.ncbi.nlm.nih.gov/pubmed/28421243

dc.identifier

10.1007/s00261-017-1151-2

dc.identifier.eissn

2366-0058

dc.identifier.uri

https://hdl.handle.net/10161/15188

dc.language

eng

dc.publisher

Springer Science and Business Media LLC

dc.relation.ispartof

Abdom Radiol (NY)

dc.relation.isversionof

10.1007/s00261-017-1151-2

dc.subject

Dual-layer CT

dc.subject

Monoenergetic image

dc.subject

SDCT

dc.subject

Spectral detector CT

dc.title

Assessment of 70-keV virtual monoenergetic spectral images in abdominal CT imaging: A comparison study to conventional polychromatic 120-kVp images.

dc.type

Journal article

duke.contributor.orcid

Chalian, Hamid|0000-0001-8357-7347

pubs.author-url

https://www.ncbi.nlm.nih.gov/pubmed/28421243

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Radiology

pubs.organisational-group

Radiology, Cardiothoracic Imaging

pubs.organisational-group

School of Medicine

pubs.publication-status

Published online

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2017 Abdominal Radiology MonoE.pdf
Size:
1.74 MB
Format:
Adobe Portable Document Format