Highly efficient detection in fluorescence tomography of quantum dots using time-gated acquisition and ultrafast pulsed laser.

dc.contributor.author

Zhang, X

dc.contributor.author

Badea, CT

dc.contributor.editor

Tromberg, Bruce J

dc.contributor.editor

Yodh, Arjun G

dc.contributor.editor

Tamura, Mamoru

dc.contributor.editor

Sevick-Muraca, Eva M

dc.contributor.editor

Alfano, Robert R

dc.coverage.spatial

United States

dc.date.accessioned

2016-12-16T16:25:27Z

dc.date.issued

2011-01-23

dc.description.abstract

Quantum dots (QDs) are widely used in fluorescence tomography due to its unique advantages. Despite the very high quantum efficiency of the QDs, low fluorescent signal and autofluorescence are the most fundamental limitations in optical data acquisition. These limitations are particularly detrimental to image reconstruction for animal imaging, e.g., free-space in vivo fluorescence tomography. In animals studies, fluorescent emission from exogenous fluorescent probes (e.g. QDs) cannot be effectively differentiated from endogenous broad-spectral substances (mostly proteins) using optical filters. In addition, a barrow-band fluorescent filter blocks the majority of the fluorescent light and thus makes signal acquisition very inefficient. We made use of the long fluorescent lifetime of the QDs to reject the optical signal due to the excitation light pulse, and therefore eliminated the need for a fluorescent filter during acquisition. Fluorescent emission from the QDs was excited with an ultrafast pulsed laser, and was detected using a time-gated image intensifier. A tissue-simulating imaging phantom was used to validate the proposed method. Compared to the standard acquisition method that uses a narrow-band fluorescent filter, the proposed method is significantly more efficient in data acquisition (by a factor of >10 in terms of fluorescent signal intensity) and demonstrated reduction in autofluorescence. No additional imaging artifact was observed in the tomographic reconstruction.

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/21373380

dc.identifier.issn

0277-786X

dc.identifier.uri

https://hdl.handle.net/10161/13278

dc.language

eng

dc.publisher

SPIE

dc.relation.ispartof

Proc SPIE Int Soc Opt Eng

dc.relation.isversionof

10.1117/12.875502

dc.title

Highly efficient detection in fluorescence tomography of quantum dots using time-gated acquisition and ultrafast pulsed laser.

dc.type

Journal article

duke.contributor.orcid

Zhang, X|0000-0002-3566-9084

duke.contributor.orcid

Badea, CT|0000-0002-1850-2522

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/21373380

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Duke Cancer Institute

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Radiology

pubs.organisational-group

School of Medicine

pubs.publication-status

Published

pubs.volume

7896

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SPIE2011_7896_78962W.pdf
Size:
330.67 KB
Format:
Adobe Portable Document Format
Description:
Published version