The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging

dc.contributor.author

Blocker, SJ

dc.contributor.author

Holbrook, MD

dc.contributor.author

Mowery, YM

dc.contributor.author

Sullivan, DC

dc.contributor.author

Badea, CT

dc.date.accessioned

2022-01-27T18:10:36Z

dc.date.available

2022-01-27T18:10:36Z

dc.date.updated

2022-01-27T18:10:35Z

dc.description.abstract

<jats:title>ABSTRACT</jats:title><jats:p>Small animal imaging has become essential in evaluating new cancer therapies as they are translated from the preclinical to clinical domain. However, preclinical imaging faces unique challenges that emphasize the gap between mouse and man. One example is the difference in breathing patterns and breath-holding ability, which can dramatically affect tumor burden assessment in lung tissue. As part of a co-clinical trial studying immunotherapy and radiotherapy in sarcomas, we are using micro-CT of the lungs to detect and measure metastases as a metric of disease progression. To effectively utilize metastatic disease detection as a metric of progression, we have addressed the impact of respiratory gating during micro-CT acquisition on improving lung tumor detection and volume quantitation. Accuracy and precision of lung tumor measurements with and without respiratory gating were studied by performing experiments with <jats:italic>in vivo</jats:italic> images, simulations, and a pocket phantom. When performing test-retest studies <jats:italic>in vivo</jats:italic>, the variance in volume calculations was 5.9% in gated images and 15.8% in non-gated images, compared to 2.9% in post-mortem images. Sensitivity of detection was examined in images with simulated tumors, demonstrating that reliable sensitivity (true positive rate (TPR) ≥ 90%) was achievable down to 1.0 mm<jats:sup>3</jats:sup> lesions with respiratory gating, but was limited to ≥ 8.0 mm<jats:sup>3</jats:sup> in non-gated images. Finally, a clinically-inspired “pocket phantom” was used during <jats:italic>in vivo</jats:italic> mouse scanning to aid in refining and assessing the gating protocols. Application of respiratory gating techniques reduced variance of repeated volume measurements and significantly improved the accuracy of tumor volume quantitation <jats:italic>in vivo</jats:italic>.</jats:p>

dc.identifier.uri

https://hdl.handle.net/10161/24255

dc.relation.isversionof

10.1101/823245

dc.title

The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging

dc.type

Journal article

duke.contributor.orcid

Mowery, YM|0000-0002-9839-2414

duke.contributor.orcid

Sullivan, DC|0000-0002-7556-5650

duke.contributor.orcid

Badea, CT|0000-0002-1850-2522

pubs.organisational-group

Duke

pubs.organisational-group

Pratt School of Engineering

pubs.organisational-group

School of Medicine

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Biomedical Engineering

pubs.organisational-group

Radiology

pubs.organisational-group

Duke Cancer Institute

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Blocker_Lung_PlosONE-2020.pdf
Size:
3.3 MB
Format:
Adobe Portable Document Format
Description:
Published version