Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

dc.description.version

Version of Record

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/20588737

dc.identifier

198210

dc.identifier.eissn

1094-4087

dc.identifier.uri

https://hdl.handle.net/10161/4250

dc.language

eng

dc.language.iso

en_US

dc.publisher

The Optical Society

dc.relation.ispartof

Opt Express

dc.relation.journal

Optics Express

dc.subject

Artifacts

dc.subject

Calibration

dc.subject

Contact Lenses

dc.subject

Cornea

dc.subject

Humans

dc.subject

Phantoms, Imaging

dc.subject

Refraction, Ocular

dc.subject

Reproducibility of Results

dc.subject

Tomography, Optical Coherence

dc.title

3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

dc.title.alternative
dc.type

Journal article

duke.contributor.orcid

Izatt, Joseph A|0000-0003-1993-2249

duke.date.pubdate

2010-4-26

duke.description.issue

9

duke.description.volume

18

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/20588737

pubs.begin-page

8923

pubs.end-page

8936

pubs.issue

9

pubs.organisational-group

Biomedical Engineering

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Duke Institute for Brain Sciences

pubs.organisational-group

Institutes and Provost's Academic Units

pubs.organisational-group

Ophthalmology

pubs.organisational-group

Ophthalmology, Corneal Diseases

pubs.organisational-group

Pratt School of Engineering

pubs.organisational-group

School of Medicine

pubs.organisational-group

University Institutes and Centers

pubs.publication-status

Published

pubs.volume

18

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
277082200021.pdf
Size:
1.14 MB
Format:
Adobe Portable Document Format