Abstract

<jats:sec> <jats:title>BACKGROUND AND OBJECTIVES:</jats:title> <jats:p>To improve the outcomes of minimally invasive, endoscopic, intracranial procedures, steerable robotic tools have been developed but still require thorough evaluation before use in a clinical setting. This paper compares a novel steerable robotic neuroendoscope tool against a standard rigid tool.</jats:p> </jats:sec> <jats:sec> <jats:title>METHODS:</jats:title> <jats:p>Seventeen participants, 8 nonmedical and 9 medical (neurosurgery residents and fellows), were recruited. The evaluation trial consisted of a task that was completed using either a rigid tool or the steerable tool, followed by the completion of a qualitative survey. Target reach time and tool movement volume (TMV) were recorded for each trial and analyzed. The tools were evaluated within a realistic phantom model of the brain.</jats:p> </jats:sec> <jats:sec> <jats:title>RESULTS:</jats:title> <jats:p>Preclinical evaluation of both tools showed that average target reach time for the steerable tool among medical personnel (15.0 seconds) was longer than that of the rigid tool (5.9 seconds). However, the average TMV for the steerable tool (0.178 cm<jats:sup>3</jats:sup>) was much lower than that of the rigid tool (0.501 cm<jats:sup>3</jats:sup>) for medical personnel, decreasing the TMV by 64.47%.</jats:p> </jats:sec> <jats:sec> <jats:title>CONCLUSION:</jats:title> <jats:p>The steerable tool required more training and practice in comparison with the standard rigid tool, but it decreased the overall endoscope movement volume, which is a source of parenchymal injury associated with endoscopic procedures.</jats:p> </jats:sec>

Department

Description

Provenance

Subjects

Citation

Published Version (Please cite this version)

10.1227/ons.0000000000000976

Publication Info

Yamamoto, Kent K, Timothy A Brumfiel, Ronghuai Qi, Joshua J Chern and Jaydev P Desai (2024). Preclinical Evaluation of a Novel Steerable Robotic Neuroendoscope Tool. Operative Neurosurgery, 26(4). pp. 389–395. 10.1227/ons.0000000000000976 Retrieved from https://hdl.handle.net/10161/30696.

This is constructed from limited available data and may be imprecise. To cite this article, please review & use the official citation provided by the journal.


Unless otherwise indicated, scholarly articles published by Duke faculty members are made available here with a CC-BY-NC (Creative Commons Attribution Non-Commercial) license, as enabled by the Duke Open Access Policy. If you wish to use the materials in ways not already permitted under CC-BY-NC, please consult the copyright owner. Other materials are made available here through the author’s grant of a non-exclusive license to make their work openly accessible.